Du verwendest einen veralteten Browser. Es ist möglich, dass diese oder andere Websites nicht korrekt angezeigt werden.
Du solltest ein Upgrade durchführen oder einen alternativen Browser verwenden.
Grafana autoscale y axis. Now I just spun up a new v...
Grafana autoscale y axis. Now I just spun up a new version 8 instance and it seems impossible to tweak I’m trying to achieve similar y-axis scale values with the old time graph. Is it possible? You could see the traffic hitting 3gbps on the old grpah, but on the new graph, without pointing your mouse on it, you Hi, I am wondering if others would find it helpful to be able to configure the "Y-Span" in the Axes & Grid settings of the Graph panel? That is, in addition to specifying I'm trying to replicate this (scatter) chart with non-standard x and y axes using Apache Echarts inside Grafana: Chart to replicate However, looking through the I am trying to plot two time-series queries on the same panel (instant metrics and rolling average), and whatever I do, I cannot make it plot it on the same scale: Whatever I do (tried hiding right axis, An option to have the Y-axis automatically scaled so a percentile of the data points, say 95%, fits on the chart. I’m pretty sure that I have been able to set Y axis steps in Grafana in the past. 1e-10). Is there a way to adjust the scale of a single Y axis without affecting the others? torkelo changed the title axis min-max Graph: Limits on Y auto scale (min max) on Jan 20, 2016 torkelo added prio/low This makes it easier to compare more than one graph’s worth of data because the axes are not shifted or stretched within visual proximity of each other. 6, CentOS What are you trying to achieve? Give non editors the chance I am sure that the data points are at least between 10-100 (referring to the y-axis) not sure why the y-axis is less than 0. To visually compare Grafana 8. Even for things that have a natural maximum (like 100%) selecting or excluding I’ve been raking my brain to try to find a way to display a number of graphs on a page to the same Y-axis scale. One of the device observed an anomaly so its y-axis is very I normally avoid setting the Y-axis maximum so the dashboard is effective for a wider range of systems. Show them, if other data makes this value become visible, else they are out of the By default, Grafana sets the range for the y-axis automatically based on the dataset. e. 5 and 9. I have multiple graphs showing motor current from various systems. eg (Linear,Log10). The max is set to 100 in Hi everyone, I am facing a problem with Y-axis scaling in Grafana when displaying multiple queries on the same panel. I have a time series panel with multiple Y axis. abs(max(Y)-min(Y))) does not exceed the configured minimum y-axis range, the minimum and maximum values on the y-axis So, I wonder if there is a way to say: “ Exclude the Columns X and Y from auto-scaling the Y-Axis. It seems the yaxis of the graph is calculated separately for each metric (device). Now I just spun up a new version 8 instance and it seems impossible to tweak the Y What happened? The auto-scaling of Y-Axis range in a time series breaks for me, if the data is smaller than some threshold (about 3. 2. 3. I have three queries: Query 1 (called analysis) has constant value of 1 Query 2 - GitHub - grafana/grafana: The open and composable observability and data visualization platform. So, I wonder if there is a way to say: “ Exclude the Columns X and Y from auto-scaling the Y-Axis. I am working on some dashboards for a client and I wondered whether it would be possible to custom scales for the Y axis (say, a tan function Y/100*pi-pi/2). Visualize metrics, logs, and traces from multiple sources An option to have the Y-axis automatically scaled so a percentile of the data points, say 95%, fits on the chart. Soft min and soft max settings can prevent small variations in the data By default, Grafana sets the range for the y-axis automatically based on the dataset. Show them, if other data makes this value become visible, else they are out of the diagrams rendering area ”? Today, the “past hour” graph and the “past 24 hours” graph are both still stuck with a Y-axis of 0 to 25, even though both are showing data values in the range 0 to 3 (the 20-call spike has This section explains how to use Time series field options to control the display of axes in the visualization and illustrates what the axis options do. This would probably be a separate setting for both min and max of the scale. How could we fix this? If we have to use a scale function, that’s fine, but is there a What happened? The auto-scaling of Y-Axis range in a time series breaks for me, if the data is smaller than some threshold (about 3. Soft min and soft max – Set a Soft min or Soft max What Grafana version and what operating system are you using? tested on v8. I would like to let views of a dashboard selectively change the Y-Axis scale using a custom Variable. Unfortunately, out of the box Grafana (v. The When used on a set of values where the range of the data (i. Is there any approach to use variables to set graph parameter like this? Can I include Hi, I’m pretty sure that I have been able to set Y axis steps in Grafana in the past. Soft min and soft max settings can prevent small variations in the data from being magnified when it's mostly flat. This would probably be a separate setting for both Hello! I have a bar chart, and the max value of each bar can be one value between 0 and 1, but sometimes, if the values are too small, it is convenient that the Y Is it possible to have min and max values for a graph that still allow the graph to autoscale itself but only within the range I specify? What I find often happens is that I get one high values that I’m not .